Logged in as:

Show all filters

Hide all filters

  • Total: 6

RADOX 125 - Drum


Huber+Suhner
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red, Black, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-55-145 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
125 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Green/yellow, Red
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-125 °C
Core colour:
Green/yellow, Red, Black
Conductor surface:
Tinned
Halogen free:
Yes
Packaging:
Drum
Min. permitted bending radius, stationary application/permanent installation:
25.5-73.5 mm
Reaction-to-fire class according to EN 13501-6:
Eca
Smoke development class according to EN 13501-6:
N/A
Euro class flaming droplets/particles according to EN 13501-6:
N/A
Euro class acidity according to EN 13501-6:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant (according to EN 60811-404):
No

RADOX 125 - Spool


Huber+Suhner
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-55-145 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
125 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Purple
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-125 °C
Core colour:
Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Red, Black, White
Conductor surface:
Tinned
Halogen free:
Yes
Packaging:
Spool HS150, Spool HS151, Spool HS200
Min. permitted bending radius, stationary application/permanent installation:
4.35-20.25 mm
Reaction-to-fire class according to EN 13501-6:
Eca
Smoke development class according to EN 13501-6:
N/A
Euro class flaming droplets/particles according to EN 13501-6:
N/A
Euro class acidity according to EN 13501-6:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant (according to EN 60811-404):
No

RADOX 125 - Conipack


Huber+Suhner
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Grey, Black, White, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-55-145 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
125 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Grey, Yellow, Brown, White, Blue
Material insulation:
Polyolefin (POE)
Core colour:
Blue, Brown, Green/yellow, Black, White
Conductor surface:
Tinned
Halogen free:
Yes
Packaging:
Drum, CK
Min. permitted bending radius, stationary application/permanent installation:
6.75 mm
Reaction-to-fire class according to EN 13501-6:
Eca
Smoke development class according to EN 13501-6:
N/A
Euro class flaming droplets/particles according to EN 13501-6:
N/A
Euro class acidity according to EN 13501-6:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant (according to EN 60811-404):
No

RADOX 125 - Industry Spool


Huber+Suhner
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-55-145 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
125 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-125 °C
Core colour:
Blue, Brown, Yellow, Grey, Green, Green/yellow, Orange, Red, Black, White
Conductor surface:
Tinned
Halogen free:
Yes
Packaging:
Spool HS150, Spool HS400, Spool HS200
Min. permitted bending radius, stationary application/permanent installation:
4.35-10.05 mm
Reaction-to-fire class according to EN 13501-6:
Eca
Smoke development class according to EN 13501-6:
N/A
Euro class flaming droplets/particles according to EN 13501-6:
N/A
Euro class acidity according to EN 13501-6:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant (according to EN 60811-404):
No

RADOX MARIN MFH-S B, Twisted pair


Huber+Suhner
Number of cores:
8-28 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyolefin
Specification material outer sheath:
Other
Colour outer sheath:
Other
Permitted cable outer temperature after assembling without vibration:
-40-120 °C
Conductor material:
Copper
Twisted cores:
Yes
Max. conductor temperature:
120 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Braiding
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black
Core colour:
Several
Conductor surface:
Tinned
Halogen free:
Yes
Min. permitted bending radius, stationary application/permanent installation:
31.5-42.3 mm
Reaction-to-fire class according to EN 13501-6:
N/A
Smoke development class according to EN 13501-6:
N/A
Euro class flaming droplets/particles according to EN 13501-6:
N/A
Euro class acidity according to EN 13501-6:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant (according to EN 60811-404):
No

RADOX MARIN MFH-S B


Huber+Suhner
Number of cores:
3 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyolefin
Specification material outer sheath:
Other
Colour outer sheath:
Other
Permitted cable outer temperature after assembling without vibration:
-40-120 °C
Conductor material:
Copper
Twisted cores:
Yes
Max. conductor temperature:
120 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Braiding
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-120 °C
Core colour:
Several
Conductor surface:
Tinned
Halogen free:
Yes
Min. permitted bending radius, stationary application/permanent installation:
17.25 mm
Reaction-to-fire class according to EN 13501-6:
N/A
Smoke development class according to EN 13501-6:
N/A
Euro class flaming droplets/particles according to EN 13501-6:
N/A
Euro class acidity according to EN 13501-6:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant (according to EN 60811-404):
No
Yes
  • Total: 6
We are using Cookies to give you a superior user experience. If you want to find out more about cookies and how we use them, please go to our cookie page. Further browsing of this site indicates that you accept our cookie policy.